<?xml version="1.0" encoding="UTF-8" ?>
<rss version="2.0" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:atom="http://www.w3.org/2005/Atom">
	<channel>
		<title>Автоматика и диспетчеризация</title>
		<link>http://asud-kip.ru/</link>
		<description></description>
		<lastBuildDate>Fri, 22 Mar 2013 19:27:26 GMT</lastBuildDate>
		<generator>uCoz Web-Service</generator>
		<atom:link href="https://asu-kip.3dn.ru/news/rss" rel="self" type="application/rss+xml" />
		
		<item>
			<title>Подключение модема IRZ MC52i к теплосчетчику &quot;Взлет ТСРВ-031&quot;</title>
			<description>&lt;h1 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;Подключение модема IRZ MC52i к теплосчетчику &quot;Взлет ТСРВ-031&quot;&lt;/span&gt;&lt;/h1&gt;&lt;div&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&lt;font face=&quot;Verdana, Geneva, Tahoma, sans-serif&quot;&gt;&lt;span style=&quot;font-size: 12px; line-height: 18px;&quot;&gt;Рекомендации по установки &amp;nbsp;модемов&amp;nbsp;IRZ MC52i&amp;nbsp;для теплосчетчиков тсрв-031.&lt;/span&gt;&lt;/font&gt;&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Сначала настроим модем подключенный к самому теплосчетчику, просмотрев множество&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;ПО по конфигурации модемов и рекомендациям по ручному программированию модемов&lt;/span&gt;&lt;/di...</description>
			<content:encoded>&lt;h1 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;Подключение модема IRZ MC52i к теплосчетчику &quot;Взлет ТСРВ-031&quot;&lt;/span&gt;&lt;/h1&gt;&lt;div&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&lt;font face=&quot;Verdana, Geneva, Tahoma, sans-serif&quot;&gt;&lt;span style=&quot;font-size: 12px; line-height: 18px;&quot;&gt;Рекомендации по установки &amp;nbsp;модемов&amp;nbsp;IRZ MC52i&amp;nbsp;для теплосчетчиков тсрв-031.&lt;/span&gt;&lt;/font&gt;&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Сначала настроим модем подключенный к самому теплосчетчику, просмотрев множество&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;ПО по конфигурации модемов и рекомендациям по ручному программированию модемов&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;font size=&quot;2&quot; style=&quot;font-size: 10pt;&quot;&gt;пришел к оптимальному выходу - использование программы&lt;/font&gt;&amp;nbsp;д&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;ля настройки модемов&amp;nbsp;&lt;/span&gt;&lt;font color=&quot;#073763&quot; style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Msetup&lt;/font&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;от&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;font face=&quot;Verdana, Geneva, Tahoma, sans-serif&quot;&gt;&lt;span style=&quot;font-size: 12px; line-height: 18px;&quot;&gt;приборов &quot;Логика - СПТ 941&quot; Качаем &lt;a href=&quot;http://www.asud-kip.ru/load/utility/programma_dlja_konfiguracii_modemov_irz_dlja_teploschetchikov_quot_logika_quot_quot_vzlet_quot/3-1-0-16&quot; target=&quot;_blank&quot; title=&quot;Скачать программу.&quot;&gt;здесь&lt;/a&gt;, в программе&amp;nbsp;прописаны&amp;nbsp;все конфигурации&lt;/span&gt;&lt;/font&gt;&lt;/div&gt;&lt;div&gt;&lt;br&gt;&lt;/div&gt;&lt;div&gt;&lt;div style=&quot;text-align: center;&quot;&gt;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/New_modem/MODRAD.png&quot; alt=&quot;Фото модема IRZ&quot; style=&quot;font-size: 8pt;&quot; align=&quot;absMiddle&quot;&gt;&lt;/div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px;&quot;&gt;Настройки для модема на прибор: Подключаем модем к порту COM1 или тот который установился у Вас виртуальным драйвером. С виртуальным портом работает (использовался конвертер RS-232 to USB от GEMBRID ). Запускаем программу Msetup.&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;br&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Выбираем &quot;Стандартные настройки GSM/CSD&quot;, далее ТСРВ-031 (Скорость лок.обмена 2400 бит&amp;#92;с).&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;В настройках программы выбираем нужный порт и жмем на зеленую кнопку в виде трегольника&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px;&quot;&gt;или двойной клик на выбранной строке&lt;/span&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px;&quot;&gt;.&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Теперь настраиваем сам прибор ТСРВ-031,заходим в настройки&amp;nbsp; параметры RS-232:&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Скорость бит/с = 2400&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Адрес в сети = 1&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Задержка = 30 (подстраиваете под свою связь,до устоичивого считывания)&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Управление = нет&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Тип соединения = модемное&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Число звонков = 2 (подбираем под себя).&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;br&gt;&lt;/div&gt;&lt;div&gt;Рекомендую устанавливать скорость 2400, так как при настройки модема при тестирование на Windows 7, скорость 2400 не обнаружена ( Привет Биллу), на старом ХР можно использовать и 4800.&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Если Вы выбрали &quot;Стандартные настройки GSM/CSD&quot;, далее ТСРВ-031 (Скорость лок.обмена 4800 бит&amp;#92;с).&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;То настраиваем ТСРВ-031 так, параметры RS-232:&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Скорость бит/с = 4800&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Адрес в сети = 1&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Задержка = 0 (&lt;/span&gt;&lt;font style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;b&gt;&lt;i style=&quot;color: rgb(0, 0, 128);&quot;&gt;обязательно&lt;/i&gt;&lt;/b&gt;&lt;/font&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;)&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Управление = нет&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Тип соединения = Прямое (&lt;/span&gt;&lt;font style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;b&gt;&lt;i style=&quot;color: rgb(0, 0, 128);&quot;&gt;обязательно, даже если подключен модем&lt;/i&gt;&lt;/b&gt;&lt;/font&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;)&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Число звонков = 0&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Но связь может быть не устойчивой (зависит от качества связи).&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Теперь &lt;a href=&quot;http://www.asud-kip.ru/load/utility/programma_nastrojki_modemov_irz_dlja_teplovycheslitelej_vkt_5_vkt_7/3-1-0-17&quot; target=&quot;_parent&quot; title=&quot;Скачать программу.&quot;&gt;скачиваем&lt;/a&gt; программу&amp;nbsp;&lt;/span&gt;&lt;font color=&quot;#073763&quot; style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;InitModem&lt;/font&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;от&amp;nbsp;&lt;/span&gt;&lt;a href=&quot;http://www.teplocom.spb.ru/&quot; title=&quot;teplocom.spb.ru&quot; style=&quot;padding: 0px; margin: 0px; outline: none; font-family: &apos;Times New Roman&apos;; font-size: 13px; color: rgb(0, 51, 153); font-weight: bold; line-height: 1.5em; background-color: rgb(255, 255, 255);&quot;&gt;(www.teplocom.spb.ru).&lt;/a&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px;&quot;&gt;И настраиваем второй модем на компьютер.&lt;/span&gt;&lt;br&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Запускаем программу,выбираем сом-порт,тип используемого модема, скорость (выбираем такую же,что и на прибор),&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;тип подключения (подключение к компьютеру).Ставим галочку отключить GPRS.&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Жмем Старт!&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;font size=&quot;2&quot; style=&quot;font-size: 10pt;&quot;&gt;При первой настройке программа выдаст ошибку, со второго раза прошивается без проблем.&lt;/font&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;В настройках компьютера (в Диспечере устройств) Порты (COM и LPT) последовательный порт (Либо конфигурация виртуального порта) выставляем&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;скорость порта ту,которую вы выбрали для модема (обязательно 2400 или 4800).&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Установка модема в Win7: в диспетчере устройств: Действие-Добавить старое устройство-Модемы- Стандартный модем-Модем-2400&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255); font-weight: bold;&quot;&gt;В вкладке &quot;модемы&quot;выбрать скорость модема равную скорости порта сом1 (2400 или 4800).&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;Ставите драйвер модема &quot;стандартный модем 9600&quot;,без разницы,ставил MC55i,МС35i.&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;в вкладке Диагностика проверяем модем, &quot;Опросить модем&quot;, модем должен ответить.&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;В Explorer в &quot;Свойствах обозревателя,подключения - добавляем подключение к нашему модему,ставим &quot;по умолчанию&quot; и&lt;/span&gt;&lt;br style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;подключаться при отсутствии сети.&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/div&gt;&lt;div&gt;&lt;span style=&quot;font-family: Verdana, Geneva, Tahoma, sans-serif; font-size: 12px; line-height: 18px; background-color: rgb(255, 255, 255); font-weight: bold;&quot;&gt;Спасибо за идеи Киповцам Инета!&lt;/span&gt;&lt;/div&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/podkljuchenie_modema_irz_mc52i_k_teploschetchiku_vzlet_tsrv_031/2013-03-22-22</link>
			<category>Диспетчеризация</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/podkljuchenie_modema_irz_mc52i_k_teploschetchiku_vzlet_tsrv_031/2013-03-22-22</guid>
			<pubDate>Fri, 22 Mar 2013 19:27:26 GMT</pubDate>
		</item>
		<item>
			<title>Компания &quot;Радиофид&quot; выпустила новый модем ATM2-232.</title>
			<description>&lt;div style=&quot;text-align: center;&quot;&gt;&lt;font size=&quot;3&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;b&gt;Компания &quot;Радиофид&quot;&amp;nbsp;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Arial, sans-serif; line-height: 21px;&quot;&gt;выпустила новый модем ATM2-232, который в автоматическом режиме организует прозрачную передачу данных по каналу GPRS.&lt;/span&gt;&lt;/b&gt;&lt;/font&gt;&lt;/div&gt;&lt;div&gt;&lt;br&gt;&lt;/div&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;font&gt;&lt;font size=&quot;3&quot;&gt;ATM2-232 представляет собой двухдиапазонный (900/1800 МГц) GSM-модем, разработанный для передачи данных по сетям сотовой связи. Модем поддерживает GPRS класс 10 и стек протоколов TCP/IP. При работе ATM2-232 &amp;nbsp;автоматически подключается к сети GPRS и устанавливает соединение с сервером, поддерживая постоянное соединение с ним или работу по расписанию. Обеспечивается прозрачное взаимодействие между конечным программным обеспечением и внешним устройством, подключенным к модему. ATM2-232 ориентирован на совместную работу со специализированным сервером iRZ Collector. Модем оснаще...</description>
			<content:encoded>&lt;div style=&quot;text-align: center;&quot;&gt;&lt;font size=&quot;3&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;b&gt;Компания &quot;Радиофид&quot;&amp;nbsp;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Arial, sans-serif; line-height: 21px;&quot;&gt;выпустила новый модем ATM2-232, который в автоматическом режиме организует прозрачную передачу данных по каналу GPRS.&lt;/span&gt;&lt;/b&gt;&lt;/font&gt;&lt;/div&gt;&lt;div&gt;&lt;br&gt;&lt;/div&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;font&gt;&lt;font size=&quot;3&quot;&gt;ATM2-232 представляет собой двухдиапазонный (900/1800 МГц) GSM-модем, разработанный для передачи данных по сетям сотовой связи. Модем поддерживает GPRS класс 10 и стек протоколов TCP/IP. При работе ATM2-232 &amp;nbsp;автоматически подключается к сети GPRS и устанавливает соединение с сервером, поддерживая постоянное соединение с ним или работу по расписанию. Обеспечивается прозрачное взаимодействие между конечным программным обеспечением и внешним устройством, подключенным к модему. ATM2-232 ориентирован на совместную работу со специализированным сервером iRZ Collector. Модем оснащен последовательным портом RS232 (разъем DB9) для подключения коммуникационного кабеля и тремя дополнительными выводами GPIO для управления внешними устройствами. Работа выводов GPIO контролируется &amp;nbsp;посредством SMS. В ATM2-232 &amp;nbsp;предусмотрено резервирование операторов связи путем переключения на вторую SIM-карту. Поддерживается переключение на резервный сервер как при потере соединения с основным, так и по сигналу с внешних выводов модема или посредством SMS-команд.Модем оснащен настраиваемым сторожевым таймером и способен работать в широком диапазоне входных напряжений питания и температур.ATM2-232 предназначен для применения в системах сбора данных, системах управления технологическими процессами, системах телеметрии и телемеханики, а также для использования в автоматизированных системах. &lt;/font&gt;&lt;b&gt;&lt;font size=&quot;2&quot; style=&quot;font-size: 10pt;&quot;&gt;Модем применяется для диспетчеризации (дистанционного снятия показаний) теплосчетчиков ВКТ-7, ТБН, Магика.&lt;/font&gt;&lt;/b&gt;&lt;/font&gt;&lt;/div&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;font size=&quot;3&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/div&gt;&lt;div style=&quot;text-align: center;&quot;&gt;&lt;font size=&quot;3&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/New_modem/MODRAD.png&quot; alt=&quot;&quot; align=&quot;absMiddle&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/div&gt;&lt;div style=&quot;text-align: center;&quot;&gt;&lt;font size=&quot;3&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/div&gt;&lt;div style=&quot;text-align: center;&quot;&gt;&lt;font size=&quot;3&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;a href=&quot;http://aqualtis55.ru/request-an-estimate/&quot;&gt;&lt;img src=&quot;https://asu-kip.3dn.ru/baner_butom/but_sale/Zakaz.gif&quot; alt=&quot;&quot; align=&quot;absMiddle&quot; style=&quot;&quot; width=&quot;200pxpx&quot; height=&quot;50px&quot; title=&quot;Купить модем&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/font&gt;&lt;/div&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;font size=&quot;3&quot; style=&quot;font-size: 12pt;&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/div&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/kompanija_radiofid_vypustila_novyj_modem_atm2_232/2013-02-19-20</link>
			<category>Новинки</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/kompanija_radiofid_vypustila_novyj_modem_atm2_232/2013-02-19-20</guid>
			<pubDate>Tue, 19 Feb 2013 08:48:32 GMT</pubDate>
		</item>
		<item>
			<title>10 дел, которыми можно заняться в пробке!</title>
			<description>&lt;h1 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px; background-color: rgb(255, 255, 255); font-weight: bold;&quot;&gt;10 дел, которыми можно заняться&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;в пробке!&lt;/span&gt;&lt;/h1&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;ul style=&quot;&quot;&gt;&lt;li style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;Можно как следует изучить и&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size: 13px;&quot;&gt;запомнить наизусть номер&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size: 13px;&quot;&gt;впереди стоящей&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size: 13px;&quot;&gt;машины.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Если у вас с собой есть моток&amp;nbsp;изоленты, можно намотать ее...</description>
			<content:encoded>&lt;h1 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px; background-color: rgb(255, 255, 255); font-weight: bold;&quot;&gt;10 дел, которыми можно заняться&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;в пробке!&lt;/span&gt;&lt;/h1&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;ul style=&quot;&quot;&gt;&lt;li style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;Можно как следует изучить и&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size: 13px;&quot;&gt;запомнить наизусть номер&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size: 13px;&quot;&gt;впереди стоящей&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-size: 13px;&quot;&gt;машины.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Если у вас с собой есть моток&amp;nbsp;изоленты, можно намотать ее на&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;руль.&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Очень красиво.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Можно стать чемпионом своего&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;сотового телефона по Тriрlе Рор,&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Snаkе-2,&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Ваllооn Shооtеr или другой&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;интеллектуальной игре.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Можно наконец детально&amp;nbsp;исследовать конструкцию&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;авторучки. Попробуйте&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;разобрать и собрать ее. А теперь&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;на время.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Можно заняться вышиванием, а&amp;nbsp;руль использовать в качестве&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;пяльцев.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Можно не спеша собрать все&amp;nbsp;женские волосы с переднего и&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;заднего сидений,&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;проверить, не осталось ли под&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;ковриками чужой помады, следов&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;обуви&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;на потолке.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Можно сделать «Вж-ж-ж-ж-ж-ж!»&amp;nbsp;и покрутить руль. Это развлечет и&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;вас,&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;и ваших соседей.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Пробка — это как раз то место,&amp;nbsp;где можно и даже нужно заняться&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;наконец&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;содержимым собственного носа.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Неторопливая обстоятельная&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;прочистка&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;носа и внимательное изучение&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;содержимого наполнят вашу&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;жизнь смыслом&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;и сделают ваши ваши пальцы&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;ловкими и сильными.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Можно продать машину и купить&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;автомобиль поближе к светофору.&lt;/span&gt;&lt;/li&gt;&lt;li&gt;&lt;font face=&quot;Arial, Tahoma, Verdana, sans-serif&quot; size=&quot;2&quot;&gt;&lt;br&gt;&lt;/font&gt;&lt;/li&gt;&lt;li&gt;&lt;span style=&quot;font-family: Arial, Tahoma, Verdana, sans-serif; font-size: 13px;&quot;&gt;Можно немного выпить. Все равно&amp;nbsp;ехать еще не скоро.&amp;nbsp;&lt;/span&gt;&lt;/li&gt;&lt;/ul&gt;&lt;/div&gt;&lt;/span&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/10_del_kotorymi_mozhno_zanjatsja_v_probke/2013-02-19-19</link>
			<category>Юмор</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/10_del_kotorymi_mozhno_zanjatsja_v_probke/2013-02-19-19</guid>
			<pubDate>Tue, 19 Feb 2013 08:30:10 GMT</pubDate>
		</item>
		<item>
			<title>Методики проверки теплотехнических характеристик ограждающих конструкций зданий и сооружений</title>
			<description>&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align:center&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:14.0pt&quot;&gt;Методики проверки теплотехнических
характеристик ограждающих конструкций зданий и сооружений&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Энергосбережение отнесено к стратегическим задачам
государства. По подсчетам специалистов, неэффективно используется, а фактически
тратится на обогрев «улицы», не менее 20–30% тепловых ресурсов. Проблема недостаточной
энергоэффективности особенно актуальна в нашем климате (низкие температуры,
высокая влажность воздуха).&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Основой повышения энергосбережения и
энергоэффективности является повышение тепловой защи...</description>
			<content:encoded>&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align:center&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:14.0pt&quot;&gt;Методики проверки теплотехнических
характеристик ограждающих конструкций зданий и сооружений&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Энергосбережение отнесено к стратегическим задачам
государства. По подсчетам специалистов, неэффективно используется, а фактически
тратится на обогрев «улицы», не менее 20–30% тепловых ресурсов. Проблема недостаточной
энергоэффективности особенно актуальна в нашем климате (низкие температуры,
высокая влажность воздуха).&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Основой повышения энергосбережения и
энергоэффективности является повышение тепловой защиты зданий и сооружений,
закладываемой и обеспечиваемой на всех этапах возведения объектов: от
проектирования до ввода объекта в эксплуатацию. &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Без эффективных и достоверных методик контроля невозможно
обеспечить выполнение норм по потреблению энергии и комфортным условиям жизни
людей.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;В данной работе рассматриваются основные методики
проверки теплотехнических характеристик ограждающих конструкций зданий и
сооружений.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Строительство зданий должно осуществляться в
соответствии с требованиями к тепловой защите зданий. Должны быть обеспечены
установленные для проживания и деятельности людей микроклимат в здании,
необходимая надежность и долговечность конструкций, климатических условий
работы технического оборудования при минимальном расходе тепловой энергии на
отопление и вентиляцию зданий за отопительный период.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-pagination:
none;mso-layout-grid-align:none;text-autospace:none&quot;&gt;В соответствии со СНиП
23-02-2003 «Тепловая защита зданий» нормируется температурный перепад между
температурой внутреннего воздуха и температурой внутренней поверхности
ограждающей конструкции, который для наружных стен составляет 4ºС.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Кроме того, в соответствии с п.5.9 СНиП 23-02-2003 «Тепловая
защита зданий», нормируется температура внутренней поверхности ограждающей
конструкции в зоне теплопроводных включений (диафрагм, сквозных швов из
раствора, стыков панелей, ребер, шпонок и гибких связей в многослойных панелях,
жестких связей облегченной кладки и др.), в углах и оконных откосах, которая
должна быть не ниже температуры точки росы внутреннего воздуха при расчетной
температуре наружного воздуха в холодный период года. Для эксплуатируемых
зданий с нормируемыми показателями микроклимата (температура воздуха 20-22º&lt;span lang=&quot;EN-US&quot;&gt;C&lt;/span&gt;, относительная влажность не
более 55%) температура точки росы составляет 10,7 º&lt;span lang=&quot;EN-US&quot;&gt;C&lt;/span&gt;. Чем ниже влажность, тем больше
разница между температурой точки росы и температурой внутреннего воздуха. Чем
выше влажность, тем температура точки росы выше и ближе к температуре
внутреннего воздуха. &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Контроль нормируемых показателей тепловой защиты и ее
отдельных элементов эксплуатируемых зданий и оценку их энергетической
эффективности выполняют путем натурных испытаний.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;mso-layout-grid-align:none;
text-autospace:none&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Основным методом определения теплотехнических
характеристик наружных ограждающих конструкций является съемка тепловизором
(тепловизионный контроль). Методика проведения данного испытания описана в ГОСТ
Р 54852-2011 «Метод тепловизионного контроля качества теплоизоляции ограждающих
конструкций». Только результаты тепловизионной съемки принимаются органами
Госстройнадзора и другими контролирующими органами в качестве подтверждения
обеспечения требуемых теплотехнических характеристик здания.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Существуют также косвенные методы определения
теплотехнических характеристик: калориметрическое определение коэффициента
теплопередачи; измерение перепадов температуры пирометром. Однако, данные
методы имеют ряд существенных недостатков, поэтому в промышленном и гражданском
строительстве имеют ограниченное применение.&amp;nbsp;
&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/p&gt;

&lt;h2&gt;&lt;b&gt;Съемка тепловизором (тепловизионный контроль, термографирование)&lt;/b&gt;&lt;/h2&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-indent:27.0pt&quot;&gt;&lt;b&gt;&lt;br&gt;&lt;/b&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: center; text-indent: 27pt;&quot;&gt;&lt;b&gt;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/teplovizor/tv1.jpg&quot; alt=&quot;Фото тепловизора&quot; style=&quot;&quot; width=&quot;200px&quot; height=&quot;140px&quot; align=&quot;absMiddle&quot;&gt;,, &amp;nbsp; &amp;nbsp; &amp;nbsp;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/teplovizor/dom.jpg&quot; alt=&quot;тепловизионная съемка&quot; width=&quot;200px&quot; height=&quot;160px&quot; align=&quot;absMiddle&quot; style=&quot;&quot;&gt;&lt;br&gt;&lt;/b&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-indent:27.0pt&quot;&gt;&lt;b&gt;&lt;br&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt&quot;&gt;Суть метода: Метод
тепловизионного контроля (термографирование) качества теплоизоляции ограждающих
конструкций основан на дистанционном измерении тепловизором полей температур
поверхностей ограждающих конструкций, между внутренними и наружными
поверхностями которых существует перепад температур, и визуализации
температурных аномалий для определения дефектов в виде областей повышенных
теплопотерь, связанных с нарушением теплоизоляции, а также участков внутренних
поверхностей ограждающих конструкций, температура которых в процессе
эксплуатации может опускаться ниже точки росы.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Тепловизионный контроль качества тепловой защиты
здания выполняют при приемке зданий в эксплуатацию с целью обнаружения скрытых
дефектов и их устранения.&amp;nbsp; &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;При обследовании здания методом термографирования,
как правило, на первом этапе следует провести термографирование наружной
поверхности здания с тем, чтобы на втором этапе производить термографирование
внутренней поверхности дефектных конструкций, обнаруженных на первом этапе.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Большинство конструктивных, технологических,
эксплуатационных и строительных дефектов теплозащиты приводят к искажению
температурного поля конструкций и обнаруживаются тепловизором. Хотя тепловизор
обладает высокой чувствительностью, для гарантированного выявления всех
возможных дефектов ограждений необходим перепад температур между внутренним и
наружным воздухом не менее 10-15°С. Именно поэтому обследования проводятся в
течение отопительного периода, когда система отопления функционирует в штатном
режиме.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt&quot;&gt;Порядок
проведения тепловизионного контроля качества теплоизоляции ограждающих
конструкций регламентируется ГОСТ Р 54852-2011 «Метод тепловизионного контроля
качества теплоизоляции ограждающих конструкций». &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt&quot;&gt;Достоинства:&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- бесконтактный характер
измерений; &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- по термограмме можно определить
температуру в каждой точке объекта; &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- большая наглядность измерений;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- низкие сроки и большая
информативность измерений;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- тепловизор позволяет измерить
температуру мгновенно;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- возможность обзорного
термографирования объекта в целом, с последующей детализацией проблемных
участков;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- имеется ГОСТ для выполнения данных
испытаний.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:35.4pt&quot;&gt;Недостатки:&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- для гарантированного выявления
всех возможных дефектов ограждений необходим перепад температур между
внутренним и наружным воздухом не менее 10-15°С;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- требуется использование
дорогостоящего оборудования. &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;h2&gt;&lt;b&gt;Калориметрическое определение коэффициента теплопередачи&lt;/b&gt;&lt;/h2&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt&quot;&gt;Суть метода: Метод
определения приведенного коэффициента теплопередачи (или сопротивления)
ограждающей конструкции заключается в измерении по площади испытываемого
участка температур, °C, внутреннего и наружного воздуха (не менее чем в &lt;st1:metricconverter productid=&quot;100 мм&quot; w:st=&quot;on&quot;&gt;100 мм&lt;/st1:metricconverter&gt; от поверхности
конструкции), средней по участку плотности теплового потока q, Вт/м2,
измеренного по расходу тепловой энергии, выделенной электронагревателем,
который размещен в специальном теплоизолированном ящике (далее по тексту -
приборе), прижатом к поверхности испытываемого в условиях стационарной
(квазистационарной) теплопередачи ограждения, с последующим расчетом
термических характеристик.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-pagination:
none;mso-layout-grid-align:none;text-autospace:none&quot;&gt;Коэффициент теплопередачи
(или сопротивления) в натурных условиях определяют на наружных ограждающих
конструкциях эксплуатируемых или полностью подготовленных к сдаче в
эксплуатацию зданий и сооружений. Выявление теплотехнически неоднородных
участков, предназначенных для проведения измерений, рекомендуется проводить
методом термографии.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-pagination:
none;mso-layout-grid-align:none;text-autospace:none&quot;&gt;Измерения в натурных
условиях выполняют в период работы системы отопления и при разности температур
воздуха снаружи и внутри не менее &lt;st1:metricconverter productid=&quot;12 ﾰC&quot; w:st=&quot;on&quot;&gt;12
 °C&lt;/st1:metricconverter&gt;. &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt&quot;&gt;Порядок
проведения испытаний регламентируется ГОСТ 31166-2003 «Метод калориметрического
определения коэффициента теплопередачи». &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-indent:27.0pt&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-indent:27.0pt&quot;&gt;Достоинства:&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;- имеется ГОСТ для выполнения данных испытаний;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;- высокая точность определения показателя коэффициента
теплопередачи.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:35.4pt&quot;&gt;Недостатки:&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- большая длительность и
трудоемкость испытаний;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- результаты испытаний дают
коэффициент теплопередачи только на конкретном участке стены, и никак не
характеризуют объект в целом; &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- требуется специализированное
оборудование;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- требуется математическая
обработка результатов испытаний;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- испытания проводятся на
эксплуатируемых или полностью подготовленных к сдаче в эксплуатацию объектах;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- инерционность измерений, так
как при измерениях температуры используются стеклянные термометры.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/p&gt;

&lt;h2&gt;&lt;b&gt;Измерение перепадов температуры пирометром
(инфракрасным термометром)&lt;/b&gt;&lt;/h2&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:35.4pt&quot;&gt;&lt;b&gt;&lt;br&gt;&lt;/b&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: center; text-indent: 35.4pt;&quot;&gt;&lt;b&gt;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/teplovizor/pirometr.jpg&quot; alt=&quot;Фото пирометр&quot; align=&quot;absMiddle&quot; style=&quot;&quot;&gt;&lt;br&gt;&lt;/b&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:35.4pt&quot;&gt;&lt;b&gt;&lt;br&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt&quot;&gt;Суть метода: Инфракрасный
метод измерения температуры основан на измерении инфракрасного (теплового)
излучения объекта и его пересчета в температуру. &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Для корректного пересчета инфракрасного излучения в
температуру, необходимо учитывать излучательную способность реальных
материалов. При прочих равных условиях и одинаковой температуре разные объекты
излучают разное количество энергии из-за различной излучательной способности. На
величину излучательной способности оказывает влияние состояние объекта (твердое
тело, жидкость или газ), фактура поверхности (гладкая, шероховатая), наличие
защитных покрытий, пленок, естественных образований вроде ржавчины, накипи и
другие факторы (например: коэффициент излучения железа оцинкованного
окрашенного и неокрашенного отличается примерно в 4 раза). Для большинства
стандартных материалов и предметов существуют сводные таблицы, по которым можно
узнать значение коэффициента и настроить пирометр для каждой конкретной
ситуации. Неправильно установленный коэффициент излучения может привести к
значительным ошибкам измерения.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Кроме того, при измерении температуры пирометром,
стоит учитывать, что данное измерение является поверхностным: если на
поверхности объекта имеется грязь, пыль, иней и тому подобное, то будет
измеряться температура только верхнего слоя поверхности, например температура
грязи. Поэтому перед измерениями необходимо убедиться, что поверхность объекта
чистая.&amp;nbsp; &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Измерения температуры поверхности ограждающих
конструкций следует производить:&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-left:36.0pt;text-align:justify;text-indent:
-9.0pt;mso-list:l1 level1 lfo1;tab-stops:list 36.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family:&quot;Courier New&quot;;
mso-fareast-font-family:&quot;Courier New&quot;&quot;&gt;­&lt;span style=&quot;font-size: 7pt; font-family: &apos;Times New Roman&apos;;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;на
поверхности пола - в середине помещения;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-left:36.0pt;text-align:justify;text-indent:
-9.0pt;mso-list:l1 level1 lfo1;tab-stops:list 36.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family:&quot;Courier New&quot;;
mso-fareast-font-family:&quot;Courier New&quot;&quot;&gt;­&lt;span style=&quot;font-size: 7pt; font-family: &apos;Times New Roman&apos;;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;на
поверхности потолка - в середине потолка;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-left:36.0pt;text-align:justify;text-indent:
-9.0pt;mso-list:l1 level1 lfo1;tab-stops:list 36.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family:&quot;Courier New&quot;;
mso-fareast-font-family:&quot;Courier New&quot;&quot;&gt;­&lt;span style=&quot;font-size: 7pt; font-family: &apos;Times New Roman&apos;;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;на
поверхности стены вне зоны влияния системы отопления - на уровне &lt;st1:metricconverter productid=&quot;1,5 м&quot; w:st=&quot;on&quot;&gt;1,5 м&lt;/st1:metricconverter&gt; от пола в середине
простенка или глухой части стены в отдалении от теплопроводных включений;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-left:36.0pt;text-align:justify;text-indent:
-9.0pt;mso-list:l1 level1 lfo1;tab-stops:list 36.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family:&quot;Courier New&quot;;
mso-fareast-font-family:&quot;Courier New&quot;&quot;&gt;­&lt;span style=&quot;font-size: 7pt; font-family: &apos;Times New Roman&apos;;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;в зоне
вертикального стыка на уровне &lt;st1:metricconverter productid=&quot;1,5 м&quot; w:st=&quot;on&quot;&gt;1,5
 м&lt;/st1:metricconverter&gt; от пола.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Замеры температур в каждой точке должны производиться
три раза. Среднее значение округляется до &lt;st1:metricconverter productid=&quot;0,1 ﾰC&quot; w:st=&quot;on&quot;&gt;0,1 °C&lt;/st1:metricconverter&gt;.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Кроме того, при выполнении измерений должны
выполняться следующие условия:&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-left:36.0pt;text-align:justify;text-indent:
-9.0pt;mso-list:l0 level1 lfo2;tab-stops:list 36.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family:&quot;Courier New&quot;;
mso-fareast-font-family:&quot;Courier New&quot;&quot;&gt;­&lt;span style=&quot;font-size: 7pt; font-family: &apos;Times New Roman&apos;;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;во время
измерений следует исключить непосредственное местное обдувание, попадание на
датчик прямых солнечных лучей и теплового излучения посторонних источников;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-left:36.0pt;text-align:justify;text-indent:
-9.0pt;mso-list:l0 level1 lfo2;tab-stops:list 36.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-family:&quot;Courier New&quot;;
mso-fareast-font-family:&quot;Courier New&quot;&quot;&gt;­&lt;span style=&quot;font-size: 7pt; font-family: &apos;Times New Roman&apos;;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;производящий
замеры должен находиться как можно дальше от исследуемой поверхности.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt&quot;&gt;Достоинства: &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- бесконтактный характер
измерений; &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- пирометр позволяет измерить
температуру мгновенно;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- дешевизна и доступность
оборудования. &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:35.4pt&quot;&gt;Недостатки: &amp;nbsp;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- искажение показаний приборов
вследствие неправильно установленного коэффициента излучения материала;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- для корректного пересчета
инфракрасного излучения в температуру необходимо учитывать излучательную
способность реальных материалов; &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- отсутствует государственный
стандарт по порядку проведения данных измерений и обработке их результатов;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- температура определяется на
некоторой сферической или эллиптической области поверхности, то есть точечно;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- результаты испытаний дают
коэффициент теплопередачи только на конкретном участке стены, и никак не
характеризуют объект в целом;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify&quot;&gt;- измерение температуры возможно производить
только на определенных участках конструкций.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;h2&gt;&lt;b&gt;Выводы:&lt;/b&gt;&lt;/h2&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;В настоящее время единственным методом определения
теплотехнических характеристик ограждающих конструкций, принимаемым органами
Госстройнадзора и другими контролирующими органами, является тепловизионная
съемка (термографирование). Данный метод позволяет выполнить проверку
характеристик ограждающих конструкций в короткие сроки. Полученные результаты обладают
большой информативностью, наглядны и не требуют трудоемкой обработки. &lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Результаты измерений по другим методам не дают
достоверной картины наличия и характера дефектов теплозащиты здания из-за
неточности измерений, искажений в показаниях прибора, неправильно принятого
коэффициента излучения, ошибок в расчетах, малого количества измерений,
отсутствия утвержденной методики проведения испытаний. Многие дефекты могут
остаться не выявленными. Кроме того, в отличие от съемки тепловизором, другими
методами невозможно выявить дефекты, связанные с повышенной инфильтрацией
наружного воздуха через щели в притворах створок окон и балконных дверей, а
также через щели в стыках строительных элементов, включая попадание наружного
воздуха внутрь помещений.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;В практике автора настоящей статьи неоднократно
встречались ситуации, когда использование простых и дешевых методик, таких как
измерение перепадов температуры пирометром, показывало отклонения от нормативов
в отдельных точках измеряемых поверхностей. Однако, последующая проверка здания
с помощью более совершенной методики (тепловизионная съемка) доказывала, что
теплотехнические характеристики здания в полной мере соответствуют регламентам.
В дальнейшем выводы, полученные при тепловизионном обследовании, подтверждались
в ходе эксплуатации здания. Своевременное применение тепловизора позволяло в
этих случаях избежать ошибочных выводов и дорогостоящих затрат на
дополнительную теплоизоляцию&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;Таким образом, на сегодня тепловизионная съемка
(термографирование) является наиболее эффективным и достоверным методом
измерения теплотехнических характеристик и широко применяется в практической деятельности
органов Госстройнадзора, Ростехнадзора, экспертных организаций и крупных
строительных компаний. &lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align:justify;text-indent:27.0pt;mso-layout-grid-align:
none;text-autospace:none&quot;&gt;&lt;br&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: center; text-indent: 27pt;&quot;&gt;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/teplovizor/rad.jpg&quot; alt=&quot;Фото тепловизором&quot; align=&quot;absMiddle&quot; style=&quot;&quot; width=&quot;200px&quot; height=&quot;160px&quot;&gt;, &amp;nbsp;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/teplovizor/tepl2.jpg&quot; alt=&quot;Фото тепловизора&quot; align=&quot;absMiddle&quot; width=&quot;200&quot; height=&quot;160&quot;&gt;,&amp;nbsp;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/teplovizor/dom2.jpg&quot; alt=&quot;Фото тепловизором&quot; width=&quot;300pxpx&quot; height=&quot;180pxpxpx&quot; style=&quot;&quot; align=&quot;absMiddle&quot;&gt;&lt;br&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;o:p&gt;&amp;nbsp;&lt;/o:p&gt;&lt;/p&gt;

&lt;h2&gt;&lt;span lang=&quot;EN-US&quot;&gt;B&lt;/span&gt;ешняков
А.В., к.т.н., доцент&lt;/h2&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/metodiki_proverki_teplotekhnicheskikh_kharakteristik_ograzhdajushhikh_konstrukcij_zdanij_i_sooruzhenij/2013-02-15-18</link>
			<category>Измерения</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/metodiki_proverki_teplotekhnicheskikh_kharakteristik_ograzhdajushhikh_konstrukcij_zdanij_i_sooruzhenij/2013-02-15-18</guid>
			<pubDate>Fri, 15 Feb 2013 10:07:47 GMT</pubDate>
		</item>
		<item>
			<title>Добавлена рубрика &quot;Видео&quot;</title>
			<description>&lt;h2 style=&quot;text-align: center;&quot;&gt;Внимание! На нашем сайте появилась рубрика &quot;Видео&quot; !&lt;/h2&gt;&lt;div&gt;&lt;font size=&quot;2&quot; style=&quot;font-size: 10pt;&quot;&gt;Проанализировав свои ежедневные труды и старания, я задался вопросом отдыха! Провозившись в рутине систем автоматики, всяких &quot;Взлетов&quot; и &quot;ВКТешек&quot; и &quot;Данфусов&quot;, я понял. ... Что на сайте чего не хватает. Делу время... Но и отдыху тоже время. И наполнил рубрику &lt;a href=&quot;http://www.asud-kip.ru/video&quot; title=&quot;Перейти на видерубоику&quot;&gt;видео&lt;/a&gt;, не только видео-уроками по системам SCADA, но разным видео-сырьем с рунета. Так, что когда&amp;nbsp;замучат&amp;nbsp;окончательно статьи о &quot;Великом и &amp;nbsp;Автоматизированном&quot;, приглашаю Вас &lt;a href=&quot;http://www.asud-kip.ru/video&quot; target=&quot;_self&quot; title=&quot;Видео &quot;online&quot;&quot;&gt;сюда&lt;/a&gt;.&lt;/font&gt;&lt;/div&gt;</description>
			<content:encoded>&lt;h2 style=&quot;text-align: center;&quot;&gt;Внимание! На нашем сайте появилась рубрика &quot;Видео&quot; !&lt;/h2&gt;&lt;div&gt;&lt;font size=&quot;2&quot; style=&quot;font-size: 10pt;&quot;&gt;Проанализировав свои ежедневные труды и старания, я задался вопросом отдыха! Провозившись в рутине систем автоматики, всяких &quot;Взлетов&quot; и &quot;ВКТешек&quot; и &quot;Данфусов&quot;, я понял. ... Что на сайте чего не хватает. Делу время... Но и отдыху тоже время. И наполнил рубрику &lt;a href=&quot;http://www.asud-kip.ru/video&quot; title=&quot;Перейти на видерубоику&quot;&gt;видео&lt;/a&gt;, не только видео-уроками по системам SCADA, но разным видео-сырьем с рунета. Так, что когда&amp;nbsp;замучат&amp;nbsp;окончательно статьи о &quot;Великом и &amp;nbsp;Автоматизированном&quot;, приглашаю Вас &lt;a href=&quot;http://www.asud-kip.ru/video&quot; target=&quot;_self&quot; title=&quot;Видео &quot;online&quot;&quot;&gt;сюда&lt;/a&gt;.&lt;/font&gt;&lt;/div&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/dobavlena_rubrika_video/2013-02-04-17</link>
			<category>Разное</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/dobavlena_rubrika_video/2013-02-04-17</guid>
			<pubDate>Mon, 04 Feb 2013 16:51:07 GMT</pubDate>
		</item>
		<item>
			<title>Обоснования установки системы диспетчеризации на приточную вентиляцию собранною на контролерах ОВЕН «ТРМ133»</title>
			<description>&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align:center&quot;&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size: 14pt; line-height: 115%; background-color: rgb(247, 247, 247); background-position: initial initial; background-repeat: initial initial;&quot;&gt;Обоснования установки системы
диспетчеризации на приточную вентиляцию, собранную на контролерах &lt;a href=&quot;http://www.aqualtis55.ru/request-an-estimate/&quot; target=&quot;_blank&quot; title=&quot;Купить и установить контролер вентиляции.&quot;&gt;ОВЕН «ТРМ133»&lt;/a&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 14pt; line-height: 115%; background-color: rgb(247, 247, 247); background-position: initial initial; background-repeat: initial initial;&quot;&gt;&lt;a href=&quot;http://www.asud-kip.ru/index/kontakty/0-6&quot; target=&quot;_blank&quot; title=&quot;Заказать систему диспетчеризации&quot;&gt;Система диспетчеризации&lt;/a&gt; позволяет
организовать плотное взаимодействие между различными подсистемами инженерного
обору...</description>
			<content:encoded>&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align:center&quot;&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size: 14pt; line-height: 115%; background-color: rgb(247, 247, 247); background-position: initial initial; background-repeat: initial initial;&quot;&gt;Обоснования установки системы
диспетчеризации на приточную вентиляцию, собранную на контролерах &lt;a href=&quot;http://www.aqualtis55.ru/request-an-estimate/&quot; target=&quot;_blank&quot; title=&quot;Купить и установить контролер вентиляции.&quot;&gt;ОВЕН «ТРМ133»&lt;/a&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 14pt; line-height: 115%; background-color: rgb(247, 247, 247); background-position: initial initial; background-repeat: initial initial;&quot;&gt;&lt;a href=&quot;http://www.asud-kip.ru/index/kontakty/0-6&quot; target=&quot;_blank&quot; title=&quot;Заказать систему диспетчеризации&quot;&gt;Система диспетчеризации&lt;/a&gt; позволяет
организовать плотное взаимодействие между различными подсистемами инженерного
оборудования, она также выполняет автоматизированный оперативный контроль и
управление. Необходимость создания подобной системы очевидна. Вот часть её
функций:&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpFirst&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;1.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Возможность регулировки параметрами
вентиляции.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;1.1&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Температура притока «день»&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;1.2&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Температура притока «ночь»&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;1.3&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Ограничение по графику температуры
обратного теплоносителя &lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;2.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Исключает ошибочное программирование
контролера.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14.0pt;line-height:
115%&quot;&gt;На компьютере будут доступны только безопасные, для работы вентиляции,
функции. Так, как при ручном вводе на самом контролере можно ошибочно ввести
данные не соответствующей функции. &amp;nbsp;Т.е.
можно ошибочно убавить температуру ограничения защиты от разморозки калорифера,
т.к. на экране прибора все параметры отображаются в собственной кодировке.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;3.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Позволяет контролировать все требуемые
параметры&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;3.1&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Температуру притока&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;3.2&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Температуру обратного теплоносителя&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;3.3&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Температуру наружного воздуха&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;3.4&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Примерное положение клапана
регулятора&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;3.5&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Наличие ошибки в контролере.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;3.6&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Угрозу разморозки калорифера&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;3.7&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Режим работы системы: дежурный,
регулировка притока, разогрев калорифера, защита от перегрева обратного
теплоносителя.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;4.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Возможность управления системой
вентиляции:&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;4.1&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Перевод системы в дежурный режим (т.е.
когда вентиляция отключена и регулирует температуру обратной воды, защищает
калорифер от разморозки)&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;4.2&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Блокировка вентиляции (вентиляция
останавливается в том положение в каком была на момент подачи команды,
блокирует доступ к программированию контролера. Например при возникновении
аварийной ситуации или на период проведения технического обслуживания)&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: center; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;&lt;a href=&quot;http://www.aqualtis55.ru&quot;&gt;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/10490138_w640_h640_trm133m2.jpg&quot; alt=&quot;Контролер автоматики&quot; style=&quot;&quot; width=&quot;600px&quot; height=&quot;200px&quot; title=&quot;Купить контролеры автоматики в Омске!&quot;&gt;&lt;/a&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;5.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Одновременное управление всеми или
несколькими контролерами по нажатию одной кнопки мыши: &lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;5.1&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Можно на одном этаже установить
единую температуру притока &lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;5.2&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Перевести все (или часть) контролеры
в дежурный режим&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;5.3&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Задать во всем здание «строгое
ограничение обратного теплоносителя»&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;6.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Возможность программирования работы
контролеров:&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;6.1&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;По расписанию (таймеру)&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;6.2&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;По очереди работы, т.е. когда
остановилась одна система (например ушла в защиту от разморозки), в это время
запускается другая сичстема.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;7.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;В случае предоставления выделенного адреса
&lt;/span&gt;&lt;span lang=&quot;EN-US&quot; style=&quot;font-size:14.0pt;line-height:115%;mso-ansi-language:
EN-US&quot;&gt;IP&lt;/span&gt;&lt;span lang=&quot;EN-US&quot; style=&quot;font-size:14.0pt;line-height:115%&quot;&gt; &lt;/span&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;возможно управление с сети интернет&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;8.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Дальнейшая интеграция с другими
контролерами автоматики и приборами учета энергии&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;8.1&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Подключиться к Теплосчетчику &lt;a href=&quot;http://www.aqualtis55.ru/request-an-estimate/&quot; target=&quot;_blank&quot; title=&quot;Купить и установить теплосчетчик в омске&quot;&gt;ВКТ-7&lt;/a&gt; и
сразу контролировать расход теплоносителя и его температуру на входе и выходе
из здания.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;8.2&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Возможно подключение к контролеру
автоматики отопления и регулировки его параметрами&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; margin-left: 57pt; text-indent: -21pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;8.3&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Также возможно подключение к приборам
учета электрической энергии.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;9.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Самый главный плюс &lt;a href=&quot;http://www.asud-kip.ru/index/kontakty/0-6&quot; target=&quot;_blank&quot; title=&quot;Заказать монтаж диспетчеризации в Омске&quot;&gt;диспетчеризации&lt;/a&gt;:
постоянная запись событий в архив компьютера. Т.е. если система вышла из строя
ночью, то просмотрев тренды, можно понять из-за какой неисправности. И предотвратить
в будущем появление такой же проблемы.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;

&lt;p class=&quot;MsoListParagraphCxSpLast&quot; style=&quot;text-align: justify; text-indent: -18pt;&quot;&gt;&lt;!--[if !supportLists]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%;mso-bidi-font-family:Calibri;
mso-bidi-theme-font:minor-latin&quot;&gt;10.&lt;span style=&quot;font-size: 7pt; line-height: normal; font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;/span&gt;&lt;!--[endif]--&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Предоставление
возможности для &lt;a href=&quot;http://www.aqualtis55.ru/services/tehnicheskoe-obsluzhivanie-sistem-ventilyacii-i-kondicionirovaniya/&quot; target=&quot;_blank&quot; title=&quot;Компания по обслуживанию вентиляции&quot;&gt;обслуживающей компании&lt;/a&gt; своевременно выявлять и оперативно
устранять неисправности в работе систем вентиляции.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpLast&quot; style=&quot;text-align: center; text-indent: -18pt;&quot;&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;&lt;img src=&quot;https://asu-kip.3dn.ru/pictures/koment.gif&quot; alt=&quot;Комментируй статьи автоматики и диспетчеризации !!!&quot;&gt;&lt;br&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/obosnovanija_ustanovki_sistemy_dispetcherizacii_na_pritochnuju_ventiljaciju_sobrannoju_na_kontrolerakh_oven_trm133/2013-02-02-15</link>
			<category>Диспетчеризация</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/obosnovanija_ustanovki_sistemy_dispetcherizacii_na_pritochnuju_ventiljaciju_sobrannoju_na_kontrolerakh_oven_trm133/2013-02-02-15</guid>
			<pubDate>Sat, 02 Feb 2013 19:00:33 GMT</pubDate>
		</item>
		<item>
			<title>Для чего нужен модем на УУТЭ или диспетчеризация узла учета тепловой энергии.</title>
			<description>&lt;h2 style=&quot;text-align: center;&quot;&gt;Для чего нужен модем на УУТЭ или диспетчеризация узла учета тепловой энергии.&lt;/h2&gt;&lt;div&gt;&lt;br&gt;&lt;/div&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;Установив модем владелец теплового узла получает возможность:&lt;/span&gt;&lt;/p&gt;&lt;blockquote style=&quot;margin: 0 0 0 40px; border: none; padding: 0px;&quot;&gt;&lt;p class=&quot;MsoListParagraphCxSpFirst&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;1.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;Оперативно передавать данные со своего узла
учета тепловой энергии обслуживающей компании.&lt;/font&gt;&lt;span style=&quot;font-size: medium;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;2.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;Снимает с себя задачу ведения журнала учета
тепловой энергии. &amp;nbsp;Т.к. в большинстве &amp;nbsp;случаев при нали...</description>
			<content:encoded>&lt;h2 style=&quot;text-align: center;&quot;&gt;Для чего нужен модем на УУТЭ или диспетчеризация узла учета тепловой энергии.&lt;/h2&gt;&lt;div&gt;&lt;br&gt;&lt;/div&gt;

&lt;p class=&quot;MsoNormal&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;Установив модем владелец теплового узла получает возможность:&lt;/span&gt;&lt;/p&gt;&lt;blockquote style=&quot;margin: 0 0 0 40px; border: none; padding: 0px;&quot;&gt;&lt;p class=&quot;MsoListParagraphCxSpFirst&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;1.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;Оперативно передавать данные со своего узла
учета тепловой энергии обслуживающей компании.&lt;/font&gt;&lt;span style=&quot;font-size: medium;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;2.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;Снимает с себя задачу ведения журнала учета
тепловой энергии. &amp;nbsp;Т.к. в большинстве &amp;nbsp;случаев при наличие модема на УУТЭ,
обслуживающая компании сама снимает ежедневно показания.&lt;/font&gt;&lt;span style=&quot;font-size: medium;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;3.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;Не требуется предоставлять постоянный &amp;nbsp;доступ на тепловой пункт для обслуживающей
компании.&lt;/font&gt;&lt;span style=&quot;font-size: medium;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;4.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;В случае необходимости получить суточный или
часовой &amp;nbsp;отчет о потребленной тепловой
энергии в кратчайшие сроки.&lt;/font&gt;&lt;span style=&quot;font-size: medium;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;5.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;Оперативное информирование, обслуживающей
компании, &amp;nbsp;о неисправности каждого прибора
входящего в состав узла учета тепловой энергии.&lt;/font&gt;&lt;span style=&quot;font-size: medium;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;6.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;Получать информация о температурном режиме
теплового узла, контроль перегрева или понижения температуры теплоносителя.&lt;/font&gt;&lt;span style=&quot;font-size: medium;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoListParagraphCxSpMiddle&quot; style=&quot;text-indent:-18.0pt;mso-list:l0 level1 lfo1&quot;&gt;&lt;font size=&quot;3&quot;&gt;7.&lt;span style=&quot;font-family: &apos;Times New Roman&apos;;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;
&lt;/span&gt;&lt;!--[endif]--&gt;Выявления, обслуживающей компанией, &amp;nbsp;погрешности преобразователей расхода
теплоносителя, погрешность по правилам учета тепловой энергии не должна быть
более четырех процентов.&lt;/font&gt;&lt;span style=&quot;font-size: medium;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/p&gt;&lt;font size=&quot;3&quot;&gt;&lt;div style=&quot;text-align: center;&quot;&gt;&lt;!--IMG1--&gt;&lt;img alt=&quot;&quot; style=&quot;margin:0;padding:0;border:0;&quot; src=&quot;http://www.asud-kip.ru/_nw/0/87112759.jpg&quot; align=&quot;&quot; /&gt;&lt;!--IMG1--&gt;&lt;/div&gt;&lt;/font&gt;&lt;/blockquote&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/dlja_chego_nuzhen_modem_na_uuteh_ili_dispetcherizacija_uzla_ucheta_teplovoj_ehnergii/2013-01-30-16</link>
			<category>Диспетчеризация</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/dlja_chego_nuzhen_modem_na_uuteh_ili_dispetcherizacija_uzla_ucheta_teplovoj_ehnergii/2013-01-30-16</guid>
			<pubDate>Wed, 30 Jan 2013 04:24:47 GMT</pubDate>
		</item>
		<item>
			<title>Журнал учета тепловой энергии и как снимать показания.</title>
			<description>&lt;body oncopy=&quot;return false;&quot;&gt;
&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align:center&quot;&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Журнал учета тепловой
энергии и как снимать показания.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Для чего нужно вести
журнал учета тепловой энергии УУТЭ?&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Прежде всего ведение журнала требуют «Правила учета тепловой
энергии» и при отсутствие журнала, отчет о затраченной тепловой энергии, «&lt;span style=&quot;font-size: 11.5pt; line-height: 115%; background-color: white; background-position: initial initial; background-repeat: initial initial;&quot;&gt;территориальная генерирующая компания&lt;/span&gt;» не
принимает. Так же одна из основных его функций это - ...</description>
			<content:encoded>&lt;body oncopy=&quot;return false;&quot;&gt;
&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align:center&quot;&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align: center;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;Журнал учета тепловой
энергии и как снимать показания.&lt;o:p&gt;&lt;/o:p&gt;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; align=&quot;center&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:14.0pt;line-height:115%&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Для чего нужно вести
журнал учета тепловой энергии УУТЭ?&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Прежде всего ведение журнала требуют «Правила учета тепловой
энергии» и при отсутствие журнала, отчет о затраченной тепловой энергии, «&lt;span style=&quot;font-size: 11.5pt; line-height: 115%; background-color: white; background-position: initial initial; background-repeat: initial initial;&quot;&gt;территориальная генерирующая компания&lt;/span&gt;» не
принимает. Так же одна из основных его функций это - &amp;nbsp;ежедневный контроль работы приборов учета и
наблюдение за работой теплового узла полностью. То есть, при записи параметров
текущей температуры на обратном трубопроводе можно проанализировать наличие
перегрева. А как&amp;nbsp; известно за перегрев
«тепловые сети» начисляют дополнительную плату. &amp;nbsp;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Как правильно
заполнить журнал?&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Образец журнала можно &lt;a href=&quot;http://u.to/A8vHAg&quot; title=&quot;http://www.akvaltis55.ru/kontragentam/zhurnal-uute/&quot; target=&quot;_blank&quot;&gt;скачать на нашем сайте&lt;/a&gt;. Прежде всего
нужно отметить, что для дальнейшего самостоятельного анализа работы УУТЭ,
показания нужно снимать в одно и тоже время (так проще отследить погрешность
приборов см. далее), заполнять журнал можно в любое удобное для Вас время, в 8
утра или в 11 ночи это - &amp;nbsp;не важно. &lt;b&gt;Не обязательно заполнять журнал в
праздничные или выходные дни, &lt;/b&gt;это допускают &amp;nbsp;&lt;span style=&quot;font-size: 11.5pt; line-height: 115%; font-family: Arial, sans-serif; background-color: white; background-position: initial initial; background-repeat: initial initial;&quot;&gt;теплоснабжающие
организации&lt;/span&gt;.&lt;b&gt; &lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Самое главное при
заполнение журнала заносить точно отображаемые, стабилизировавшиеся показания. &lt;/b&gt;Т.е
понаблюдать за цифрами 20 – 40 секунд, потому что прибор при выходе из
дежурного режима не сразу отображает корректные данные, а после записать их в
журнал. &amp;nbsp;Единицы измерения параметров
записывать ненужно.&lt;b&gt;&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Первым заполняется дата и время, после в журнал заносятся
данные о текущих и итоговых параметрах приборов. Это температура подающего и
обратного трубопровода (Т1 и Т2) , мгновенный расход теплоносителя (&lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;1 и &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;2). Заполняются данные итоговых
показаний объема (М1 и М2 или V1 и &lt;span lang=&quot;EN-US&quot;&gt;V&lt;/span&gt;2) и количество тепловой энергии (&lt;span lang=&quot;EN-US&quot;&gt;Q&lt;/span&gt;&lt;span lang=&quot;EN-US&quot;&gt; &lt;/span&gt;или Е). Также
записывается время работы &amp;nbsp;прибор а (ВНР,
Тр у разных приборов параметр время работы обозначается по разному).
Вписываются показания счетчика горячей воды (если на узле есть открытый
водоразбор) с циферблата механического расходомера.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Сколь после запятой?&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;В правилах учета тепловой энергии нет строгих требований к
заполнению данных, но всё таки рекомендуем придерживаться следующих норм. &amp;nbsp;&amp;nbsp;Количество цифр, при заполнение, &amp;nbsp;после запятой у каждого параметра по разному.
При записи температур достаточно и одной цифры, допускается просто записать
целое число. Мгновенный расход записываете не менее одной цифры после запятой,
для вычисления погрешности (см. ниже), лучше писать две цифры. При записи
итогового расхода следует учитывать величину расхода &amp;nbsp;теплоносителя. Т.е. если расход не большой, то
нужно писать хотя бы один знак после запятой (особенно на горячей воде). Если
узел с большой нагрузкой, достаточно записать целое число. Количество тепловой
энергии рекомендуем записывать не менее двух знаков после запятой, так как это Ваши
затраты на тепло, &lt;span style=&quot;font-size: 11.5pt; line-height: 115%; font-family: Arial, sans-serif; background-color: white; background-position: initial initial; background-repeat: initial initial;&quot;&gt;здесь нужна точность&lt;/span&gt;.
&amp;nbsp;Время работы фиксируется только целыми
числами.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Как самостоятельно
проанализировать данные?&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Прежде всего смотрим время прибора оно должно быть примерно
одинаковое с реальным. Обычно, из практики, сбои работы процессора прибора
проявляются в отображении (пропадают или моргают символы) времени.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;Переходим к
температурам. Смотрим температуру подающего и обратного трубопровода. Анализ
температур заключается в проверке исправности термосопротивлений - это
проверяется легко смотрите на любой, рядом стоящий, термометр (спиртовой, биметаллический)
и сравниваете показания. Если показания значительно отличаются, рекомендуем Вам
в кратчайшие сроки информировать обслуживающую компанию.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Самое главное!
Погрешность!&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Анализируем мгновенный расход &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;1 и &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;2. При просмотре мгновенного расхода можно узнать есть ли
погрешность в измерениях приборов. По требованиям &lt;b&gt;погрешность не должна превышать &amp;nbsp;4 (четырех) процентов&lt;/b&gt;. Погрешность
посчитать очень просто по формуле: &lt;b&gt;( (&lt;/b&gt;&lt;b&gt;&lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;1-&lt;/b&gt;&lt;b&gt;&lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;2)/&lt;/b&gt;&lt;b&gt;&lt;span lang=&quot;EN-US&quot;&gt;Gmin&lt;/span&gt;)*100=% &lt;/b&gt;погрешности,
&lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;1 и &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;2 это мгновенный расход , а &lt;span lang=&quot;EN-US&quot;&gt;Gmin&lt;/span&gt; – это наименьшее текущее
показание расхода, на момент расчета погрешности. &amp;nbsp;&lt;b&gt;Рассмотрим
на примере: &lt;/b&gt;снимаем показания с прибора:&amp;nbsp;
&amp;nbsp;&lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;1=7,9 м.куб/час , &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;2= 7,7, считаем:&amp;nbsp; ((7,9-7,7)/7,7)*100= 2,59% - прибор работает
в приделах!&amp;nbsp; Другой пример: &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;1=7,9 м.куб/час , &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;2= 7,1, считаем:&amp;nbsp; ((7,9-7,1)/7,1)*100= 11,26% - звоним
инженерам обслуживающей компании. Так при ежедневном расчете погрешности, уже
примерно через неделю человек, снимающий постоянно показания, уже «на глаз»
определяет правильность работы прибора.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Спокойствие, только
спокойствие!&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;При проверке
погрешности стоит учитывать несколько фактов, не следует «бить тревогу», если у
вас кратковременно появилась цифра более 4 процентов, может просто не
стабилизировался расход теплоносителя. Это часто наблюдается на
автоматизированных узлах, когда клапан-регулятор закрылся, в процессе
регулировки, а прибор ещё не проанализировал расход. Так же, не стоит забывать
об &lt;b&gt;узлах с открытым водоразбором&lt;/b&gt;,&amp;nbsp; у них проанализировать погрешность возможно
только при закрытом горячем водоснабжение. Потому что погрешность это и есть
«дельта» между втекающем и вытекающем теплоносителе. На таких узлах погрешность
можно точно проанализировать только сняв показания за большой период времени,
либо если в прибор заведен импульс от счетчика горячей воды и он отображается
на вычислителе как параметр &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;3,
то погрешность можно посчитать по формуле: ((&lt;span lang=&quot;EN-US&quot;&gt;Gmax&lt;/span&gt;-(&lt;span lang=&quot;EN-US&quot;&gt;Gmin&lt;/span&gt;+&lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;3)/&lt;span lang=&quot;EN-US&quot;&gt;Gmax&lt;/span&gt;)*100=% погрешности, где &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;&lt;span lang=&quot;EN-US&quot;&gt; &lt;/span&gt;&lt;span lang=&quot;EN-US&quot;&gt;max&lt;/span&gt;&lt;span lang=&quot;EN-US&quot;&gt; &lt;/span&gt;–
это мгновенный расход трубопровода с большим расходом теплоносителя, &lt;span lang=&quot;EN-US&quot;&gt;Gmin&lt;/span&gt; – это расход
трубопровода с меньшим расходом теплоносителя (с этого трубопровода и идет
водоразбор ), а &lt;span lang=&quot;EN-US&quot;&gt;G&lt;/span&gt;3 – это
мгновенный расход счетчика горячей воды (ГВС) , но так как расход ГВС не
стабилен, то и погрешность на этих узлах выявить в момент снятия показаний
сложно. &lt;b&gt;При появление погрешности, &lt;/b&gt;на
узлах с закрытым ГВС, прежде всего нужно самостоятельно проанализировать
ситуацию. Не появился ли у Вас несанкционированный водоразбор. Практика
показывает, что в 50% случаев появления погрешности, - это &amp;nbsp;либо течь в поврежденном трубопроводе, &lt;b&gt;либо кто-то берет воду из &lt;/b&gt;&lt;b&gt;&lt;span style=&quot;font-size: 11.5pt; line-height: 115%; background-color: white; background-position: initial initial; background-repeat: initial initial;&quot;&gt;отопительных
приборов&lt;/span&gt;.&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Итоги.&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;Анализ итогов &amp;nbsp;прост. &lt;span lang=&quot;EN-US&quot;&gt;V&lt;/span&gt;1 или М1 и &lt;span lang=&quot;EN-US&quot;&gt;V&lt;/span&gt;2 или М2, а так же &lt;span lang=&quot;EN-US&quot;&gt;Q&lt;/span&gt;&lt;span lang=&quot;EN-US&quot;&gt; &lt;/span&gt;или Е должны
ежедневно увеличиваться, на количество расходуемого теплоносителя. Т.е. если у
Вас одинаковая цифра показаний итогов за вчера и сегодня, значит - &amp;nbsp;прибор не считает. В этом случае обязательно
информируйте обслуживающую организацию, для устранения неисправности. Время
работы прибора тоже должно ежедневно увеличиваться на 24 часа (при условии что,
прибор исправен и Вы в одно и тоже время снимаете показания). В некоторых
приборах время работы прибора не отображается, так что это поле не заполняется.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;Лето! Следует ли
вести журнал в &lt;/b&gt;&lt;b&gt;&lt;span style=&quot;font-size: 11.5pt; line-height: 115%; background-color: white; background-position: initial initial; background-repeat: initial initial;&quot;&gt;межотопительный&lt;/span&gt; сезон?&lt;o:p&gt;&lt;/o:p&gt;&lt;/b&gt;&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;На узлах, &amp;nbsp;где
отсутствует горячее водоснабжение из тепловых сетей ведение журнала в между
отопительный сезон не требуется. На узлах с открытым&amp;nbsp; водоразбором следует ежедневно записывать
показания счетчика горячей воды.&lt;/p&gt;

&lt;p class=&quot;MsoNormal&quot; style=&quot;text-align: justify;&quot;&gt;&lt;b&gt;&amp;nbsp;&lt;/b&gt;&lt;/p&gt;&lt;p&gt;&lt;/p&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/zhurnal_ucheta_teplovoj_ehnergii_i_kak_snimat_pokazanija/2013-01-19-14</link>
			<category>Измерения</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/zhurnal_ucheta_teplovoj_ehnergii_i_kak_snimat_pokazanija/2013-01-19-14</guid>
			<pubDate>Sat, 19 Jan 2013 14:32:12 GMT</pubDate>
		</item>
		<item>
			<title>Диспетчеризация в России</title>
			<description>&lt;h1 style=&quot;text-align: center; margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background-color: rgb(255, 255, 255); font-family: Arial, Verdana, Tahoma, Helvetica, sans-serif; color: rgb(124, 149, 104);&quot;&gt;&lt;font style=&quot;margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background-color: transparent; font-size: 18pt;&quot; size=&quot;5&quot;&gt;Диспетчеризация в России&lt;/font&gt;&lt;/h1&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;Проблема организации круглосуточного контроля за состоянием тепловых сетей и работой оборудования систем теплоснабжения (ЦТП, ИТП) в большинстве регионов РФ не решена.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; backgrou...</description>
			<content:encoded>&lt;h1 style=&quot;text-align: center; margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background-color: rgb(255, 255, 255); font-family: Arial, Verdana, Tahoma, Helvetica, sans-serif; color: rgb(124, 149, 104);&quot;&gt;&lt;font style=&quot;margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background-color: transparent; font-size: 18pt;&quot; size=&quot;5&quot;&gt;Диспетчеризация в России&lt;/font&gt;&lt;/h1&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;Проблема организации круглосуточного контроля за состоянием тепловых сетей и работой оборудования систем теплоснабжения (ЦТП, ИТП) в большинстве регионов РФ не решена.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;Разработка и внедрение систем оперативного диспетчерского управления и контроля является необходимым условием для более эффективного управления работой системы теплоснабжения, более качественного снабжения потребителей тепловой энергией. Одновременно обеспечивается безопасная работа системы благодаря предоставлению информации о режимах и параметрах в любой момент времени, что дает возможность оперативно реагировать на аварийные и внештатные ситуации.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;В России с развитием коммерческого учета тепла возможностями диспетчеризации все чаще интересуются тепловые компании. Подключение ЦТП и ИТП к сетям сбора данных может не только облегчить контроль и управление оборудованием, но и упростить ведение расчетов за поставляемые энергоресурсы как с теплогенерирующими предприятиями, так и с управляющими компаниями и ТСЖ, позволит контролировать работоспособность приборов учета.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;Системы диспетчеризации системы теплоснабжения обеспечивают:&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· реальную и полную картину состояния всех объектов в любой момент времени;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· круглосуточный мониторинг контролируемых объектов по перечню параметров;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· возможность выдачи аварийных сообщений на экран монитора, принтер или звуковых и световых предупреждений о нештатных и аварийных ситуациях;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· подсчет времени работы оборудования и предупреждение о необходимости проведения профилактических и регламентных работ и, за счет этого, продление срока службы инженерных систем;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· создание единой базы оперативных и архивных параметров технологических процессов (температура, давление, расход, тепловая мощность и количество тепловой энергии теплоносителей, работоспособность оборудования и т. д.);&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· дистанционную диагностику оборудования и каналов связи;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· генерацию отчетов об отпуске и потреблении энергии и энергоносителя, отчетов о неиспользованной тепловой энергии по результатам контроля;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· ведение журнала событий;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· представление информации в удобном для анализа виде (таблицы, графики, диаграммы);&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· дистанционный диспетчерский контроль за возникновением нештатных ситуаций на автоматизированных объектах;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· систему контроля доступа на автоматизированные объекты;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· расширение возможностей обслуживающего персонала при сокращении численности;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· возможность сбора статистической информации и прогнозирования;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· коммерческий учет потребления энергоресурсов (тепло, горячая вода, газ, электроэнергия).&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;В зависимости от характеристик автоматизируемого объекта и объема обрабатываемой информации, структура построения систем диспетчеризации реализуется в каждом случае индивидуально.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;Эффективность программ, обеспечивающих функционирование диспетчерской службы, во многом зависит от правильной организации каналов связи с объектами и организации компьютерной сети между подразделениями и службами предприятия. Необходимо предусмотреть элементы, обеспечивающие резервирование компьютерной сети, а также обеспечить серверы и оборудование каналов связи системой гарантированного электропитания.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;Каналы связи между различными уровнями системы могут быть проводными и беспроводными, с использованием выделенных и коммутируемых телефонных линий, локальных компьютерных сетей, сетей сотовой связи, радиоканалов и т.п. Используются технологии GPRS, Ethernet, WiFi и др.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;Современные технологии позволяют решить все эти задачи и обеспечить высокие скорости передачи информации.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;Диспетчеризация системы теплоснабжения позволяет осуществить:&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· регулирование подачи количества теплоты в системы отопления в зависимости от изменения параметров наружного воздуха;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· ограничение максимального расхода воды из тепловой сети на тепловой пункт путем перекрытия клапана регулятора теплоты на отопление;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· поддержание требуемого перепада давлений в подающем и обратном трубопроводе тепловых сетей на вводе ИТП;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· поддержание заданной температуры воды, которая поступает в систему горячего водоснабжения здания;&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;· анализ теплопотребления в различные сезоны – зима, лето, межсезонье – и определение алгоритма работы системы для каждого такого периода.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;h1 style=&quot;margin: 0px; padding: 0px; border: 0px; font-size: 12pt; vertical-align: baseline; background-color: rgb(255, 255, 255); font-family: Arial, Verdana, Tahoma, Helvetica, sans-serif; color: rgb(124, 149, 104);&quot;&gt;&lt;font size=&quot;3&quot; style=&quot;margin: 0px; padding: 0px; border: 0px; vertical-align: baseline; background-color: transparent;&quot;&gt;Заключение&lt;/font&gt;&lt;/h1&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;При грамотном подходе к реализации проектов систем диспетчеризации, можно значительно экономить тепловую энергию за счет ее эффективного использования и снизить эксплуатационные издержки, за счет сокращения обслуживающего персонала.&amp;nbsp;&lt;/span&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;br style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;&lt;span style=&quot;color: rgb(34, 34, 34); font-family: Verdana, Arial, sans-serif; font-size: 13px; line-height: 17px; background-color: rgb(255, 255, 255);&quot;&gt;По оценкам специалистов внедрение указанных систем приводит к экономии тепловой энергии приблизительно на 10-20%!!!, &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;&lt;/span&gt;&lt;font color=&quot;#222222&quot; face=&quot;Verdana, Arial, sans-serif&quot; size=&quot;2&quot;&gt;&lt;span style=&quot;line-height: 17px;&quot;&gt;http://energosber.info&lt;/span&gt;&lt;/font&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/dispetcherizacija_v_rossii/2013-01-19-13</link>
			<category>Диспетчеризация</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/dispetcherizacija_v_rossii/2013-01-19-13</guid>
			<pubDate>Fri, 18 Jan 2013 22:02:56 GMT</pubDate>
		</item>
		<item>
			<title>ВИДЫ ЭЛЕКТРИЧЕСКИХ СХЕМ ПРИМЕНЯЕМЫХ В РАСПРЕДЕЛИТЕЛЬНЫХ СЕТЯХ</title>
			<description>&lt;div style=&quot;text-align: center; font-family: Verdana;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-weight: bold; font-size: 14pt;&quot;&gt;ВИДЫ ЭЛЕКТРИЧЕСКИХ СХЕМ ПРИМЕНЯЕМЫХ В РАСПРЕДЕЛИТЕЛЬНЫХ СЕТЯХ&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;В электрических сетях широко используют электрические схемы. Понятие схема имеет следующие значения:&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;1. Схема — чертеж, графическое изображение электрооборудования и цепей связи. Различают по назначению схемы первичных и вторичных цепей, защиты, сигнализации, управления и др. Различают также схемы принципиальные и монтажные. Имеется множество и других схем. В данном пособии будут встречаться схемы первичных и вторичных...</description>
			<content:encoded>&lt;div style=&quot;text-align: center; font-family: Verdana;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255); font-weight: bold; font-size: 14pt;&quot;&gt;ВИДЫ ЭЛЕКТРИЧЕСКИХ СХЕМ ПРИМЕНЯЕМЫХ В РАСПРЕДЕЛИТЕЛЬНЫХ СЕТЯХ&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;В электрических сетях широко используют электрические схемы. Понятие схема имеет следующие значения:&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;1. Схема — чертеж, графическое изображение электрооборудования и цепей связи. Различают по назначению схемы первичных и вторичных цепей, защиты, сигнализации, управления и др. Различают также схемы принципиальные и монтажные. Имеется множество и других схем. В данном пособии будут встречаться схемы первичных и вторичных цепей, принципиальные, полнолинейные, однолинейные, монтажные и развернутые.&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;2. Схема — совокупность элементов и цепей связи между ними, выполняющая определенную функцию. Например, на подстанциях различают электрооборудование главной схемы и собственных нужд.&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;Первичные цепи — цепи основных технологических напряжений, по которым проходит основной поток энергии от источников к приемникам (потребителям). Назначение первичных цепей — выработка, преобразование, передача и распределение электрической энергии.&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;Первичные цепи подразделяют на главную схему и собственные нужды.&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;Цепи главной схемы — цепи, предназначенные для выработки, преобразования и распределения основного потока электроэнергии. Собственные нужды предназначены для обеспечения работы основного оборудования, в том числе, электрического, например, питание электродвигателей вентиляторов, электрическое освещение установки и др. Вторичные цепи — цепи напряжением до 1 кВ, предназначенные для выполнения функций управления, включая диспетчерское, автоматики, защиты, контроля, измерений, учета электроэнергии, сигнализации и др.&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;Электрические схемы подразделяют на полнолинейные и однолинейные. Полнолинейная (в трехфазных цепях — трехлинейная) схема характеризуется тем, что на ней показывают электрооборудование всех (трех) фаз.&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;Однолинейная схема отличается тем, что на ней показывают оборудование только одной (средней) фазы. Если какое-либо оборудование установлено не во всех фазах, то это отличие на схеме должно быть показано. Например, если трансформаторы тока (ТТ) установлены только в фазах А и С, то на однолинейной схеме должны быть показаны ТТ в этих фазах. Электрическая однолинейная схема главных цепей с краткими характеристиками основного электрооборудования называется главной схемой.&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;Принципиальной схемой называют схему, на которой с целью упрощения и лучшего понимания принципа действия объекта второстепенные, не относящиеся к рассматриваемой задаче, элементы не показаны. Монтажные схемы необходимы для производства работ по установке аппаратуры и монтажу электрических соединений.&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;Монтажные схемы разнообразны по назначению. Отметим только некоторые из них. Схема заполнения распределительного устройства — однолинейная схема, нанесенная на фоне строительной части (плана сооружения).&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;Схема кабельных трасс — обозначение на фоне упрощенного генерального&lt;/span&gt;&lt;/div&gt;&lt;div style=&quot;font-family: Verdana; text-align: justify;&quot;&gt;&lt;span style=&quot;background-color: rgb(255, 255, 255);&quot;&gt;&amp;nbsp;плана трасс и конструкций кабельных линий, трансформаторных подстанций и распределительных пунктов. Развернутые схемы вторичных цепей широко применяются при монтажно-наладочных работах. На таких схемах выделяют функциональные группы цепей, например, включения и отключения выключателя, отдельной защиты и т. д. При этом часто получается, что обмотка реле управления каким-либо аппаратом находится в одной части схемы, а его контакты — в различных ее частях.&lt;/span&gt;&lt;/div&gt;</content:encoded>
			<link>https://asu-kip.3dn.ru/news/vidy_ehlektricheskikh_skhem_primenjaemykh_v_raspredelitelnykh_setjakh/2013-01-19-12</link>
			<category>Разное</category>
			<dc:creator>kipovec</dc:creator>
			<guid>https://asu-kip.3dn.ru/news/vidy_ehlektricheskikh_skhem_primenjaemykh_v_raspredelitelnykh_setjakh/2013-01-19-12</guid>
			<pubDate>Fri, 18 Jan 2013 21:58:30 GMT</pubDate>
		</item>
	</channel>
</rss>